Part number 550-110-282/1108
30
GOLD
CGs-4E Gas-Fired Water Boiler — Boiler Manual
Start-up if boiler doesnt start . . .7c
1. Loose connections, blown fuse or service switch
off?
2. High limit switch set below boiler water tempera-
ture?
3. Thermostat set below room temperature?
4. Gasnotturnedonatmeterorboiler?
5. Incoming gas pressure less than:
5”w.c.fornaturalgas?
11”w.c.forpropanegas?
6. If none of the above corrects the problem, refer to
Troubleshooting,Section11 of this manual.
Check for: