Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service
technician or the gas supplier.
If the information in this manual is not followed exactly, a fire or
explosion may result, causing property damage, personal injury or
loss of life.
Part Number 550-110-592/1000
Gas-Fired Boilers
CGa, CGi, CGs, EG,
EGH, LGB, PEG, PFG
User’s
Information
Manual
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - EGH, LGB, PEG, PFG

Do not store or use gasoline or other flammable vapors and liquids in thevicinity of this or any other appliance.WHAT TO DO IF YOU SMELL GAS• Do not t

Page 2 - Please read this page first

10 Part Number 550-110-592/1000Probe type— See Figure 81. Clean probe type low water cutoff for properoperation.a. Turn off power to boiler and wait 5

Page 3 - Air contamination

11Part Number 550-110-592/1000Operate boiler relief valve❏ Service every 6 months . . . . . . . . .To avoid water damage or scaldingdue to valve oper

Page 4 - Boiler components

12 Part Number 550-110-592/1000Follow boiler shutdown procedure❏ End-of-season shutdown . . . . . . . .1. Follow “TO TURN OFF GAS TO APPLIANCE” onthe

Page 5 - (steam only)

13Part Number 550-110-592/1000Lighting instructionsFOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE• Do not t

Page 6 - ANNNUAL START-UP

14 Part Number 550-110-592/1000• Gas valve — Robertshaw 7200FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE

Page 7 - User maintenance procedures

15Part Number 550-110-592/1000FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE• Do not try to light any appl

Page 8 - Part Number 550-110-592/1000

16 Part Number 550-110-592/1000FOR YOUR SAFETY READ BEFORE OPERATINGOPERATING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE• Do not try to light any ap

Page 9 - — CGs boilers only

17Part Number 550-110-592/1000FOR YOUR SAFETY READ BEFORE OPERATINGOPERATING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE• Do not try to light any app

Page 10 - Float type — See Figure 7

18 Part Number 550-110-592/1000FOR YOUR SAFETY READ BEFORE OPERATINGOPERATING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE• Do not try to light any ap

Page 11 - Clean gauge glass

19Part Number 550-110-592/1000FOR YOUR SAFETY READ BEFORE OPERATINGOPERATING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE• Do not try to light any app

Page 12 - Lighting instructions

2 Part Number 550-110-592/1000Please read this page firstHow to use thismanual . . .The User’s Information Manual provides information to the boiler o

Page 13

20 Part Number 550-110-592/1000FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE• Do not try to light any app

Page 14

21Part Number 550-110-592/1000FOR YOUR SAFETY READ BEFORE OPERATINGOPERATING INSTRUCTIONSTO TURN OFF GAS TO THE APPLIANCE• Do not try to light any app

Page 15

22 Part Number 550-110-592/1000ANNUAL SHUTDOWN PROCEDURE• Do not try to light any appliance.• Do not touch any electric switch; do not useany phone in

Page 16 - Operating instructions

23Part Number 550-110-592/1000Common problems and solutionsSymptom Common Causes Possible CorrectionsRapid cycling — boiler turns on and off frequentl

Page 17

24 Part No. 550-110-592/1000Weil-McLain Limited Warranty forResidential & Commercial Cast Iron BoilersWeil-McLain500 Blaine StreetMichigan City, I

Page 18

3Part Number 550-110-592/1000Failure to adhere to the guidelines on this page can result in severe personal injury, death or substantialproperty damag

Page 19

4 Part Number 550-110-592/100059210Boiler components592111 Gas valve2 Pilot burner3 Main burner4 Gas manifold/orifices5 Control module6 Inducer (CGi a

Page 20

5Part Number 550-110-592/1000▲▲59215(PFG-5only)(PFG-5 only)▲▲Not shown▲1 Gas valve2 Pilot burner3 Main burner4 Gas manifold/orifices5 Control module7

Page 21

6 Part Number 550-110-592/1000Maintain boiler using schedule belowTankless water heater (EG and EGHonly)If boiler is used to supply domestic hot water

Page 22

7Part Number 550-110-592/1000User maintenance proceduresDo not attempt to place boiler in operation if spillswitch cuts off gas flow. Immediately call

Page 23 - Common problems and solutions

8 Part Number 550-110-592/1000❏ Check daily . . . . . . . . . . . . . . . . .Air openings1. Verify that combustion and ventilation air openingsto the

Page 24 - Michigan City, IN 46360-2388

9Part Number 550-110-592/1000Figure 4Automatic airventAutomatic air vents (if used)1. See Figure 4.2. Remove the cap from anyautomatic air vent in the