Weil-mclain 550-141-830/1202 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chaudière à eau Weil-mclain 550-141-830/1202. Weil-McLain 550-141-830/1202 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
For future reference, leave this manual
with other boiler instructions
in the envelope provided with the boiler.
Maintenance
and Service
Guide
Part No. 550-141-830/1202
SGO Series 3 Oil-Fired Steam Boiler
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Maintenance

For future reference, leave this manual with other boiler instructions in the envelope provided with the boiler.Maintenance and Service GuidePart No.

Page 2 - Read This Page First

10Fill the system:1. Do not fill (except for leakage tests) until boiler is ready to be fired.2. Fill to normal water line as indicated on jacket

Page 3 - For Your Safety

11Detailed Service ProceduresControls requiring annual service:FLOAT-TYPE LOW WATER CUTOFF:Follow instructions to blowdown cutoff on page 4. Also ref

Page 4 - Routine Maintenance Schedule

Part No. 550-141-830/1202

Page 5 - Start-up

2Hazard DefinitionsFollowing terms are used to bring attention to the presence of hazards of various risk levels, or to important information concernin

Page 6

3For Your SafetyTips for steam systems: Check boiler and system piping for leaks. Continual makeup water will reduce boiler life. Minerals ca

Page 7 - COMMON CAUSES

4Routine Maintenance ScheduleThe schedule below is specifically designed for the homeowner. Please read pages 2 and 3 before proceeding.Beginning each

Page 8 - Annual Service Check List

5Start-upSGO Boiler with Float-Type Low Water Cutoff(See Page 6 for Probe-Type Low Water Cutoff)Figure 1Gauge Glass2. Correct problems found in step

Page 9

62. Correct problems found in step #1. If burner does not fire, press reset button on burner primary control only once. Repeated presses will

Page 10 - Detailed Service Procedures

7 The problems and corrections above represent common situations that can occur. There may be others not listed above. It is important always

Page 11

8 The procedures and information on pages 8 through 11 are intended only for a qualified service technician who has the necessary equipment to inspe

Page 12 - Part No. 550-141-830/1202

9Cleaning boiler flueways: Make sure all electrical connec-tions to boiler are turned off and wait until boiler is warm, not hot, before cleanin